Downloads
Find & download all you need to get to know Peblar better
The latest firmware update introduces the fix for socket chargers which have Keep Locked enabled.
Fixes and improvements
- Fixed an issue that prevented socket chargers with Keep Locked enabled from starting a charging session after a restart
Get the most from your hardware and update the charger via the web interface.
Known issue with socket chargers
Users with Keep Locked set to on may experience charging interruptions after updating to firmware 1.9.1. If you have a socket variant and have installed this update, we recommend updating to firmware 1.9.2, which fixes this issue.
What's new in 1.9.1
- Xemex Smart Connect: improved support via direct ethernet connection. Previously, connecting a Xemex Smart Connect via a direct ethernet connection required manually configuring an IP address. This is now handled automatically when Xemex Smart Connect is selected as the measurement source.
Fixes and improvements
- Fixed an issue where a HomeWizard P1 meter connection recovering from a temporary drop-out could get stuck disabled (for example current limited to 16A, or solar limiting removed) until the charger was rebooted
Firmware 1.9.0 is the same as the previous version.
Customisation c1.15
Added backoffices:
- Chargemap (Default)
- Chargemap (Business)
- ChargePilot
- Enjoyelec
- GetLyv
- GreenPoint EV
- Groendus (Coolblue)
- Joulo
- LMS (50five Coolblue)
- Plugchoice
- Powerverse
- Spirii
- Vespr
- YES55
- Zeres
Changes and improvements:
- Updated Virta (Essent) URL
- Renamed Groendus to Groendus (Default)
- Added support for the ChargePilot Controller
Firmware 1.9.0
- Xemex Smart Connect support
- Adjustable Customer ID
- Manual fill-in IP address HomeWizard/Xemex Smart Connect
- Addition of selected Eastron meters
Customisation c1.14
Added backoffices:
- ChargeAngels
- Blue Current
- ClenergyEV
- DKV (SIM)
- DKV (LAN)
- Fuuse
- Laadpaal Totaal
- LichtBlick eMobility
- MaxxEnergy
- Monta (Stroohm)
Changes and improvements:
- Renamed E-flux to E-Flux by Road
- Renamed Monta to Monta (Default)
- Updated all E-Flux URLs to ocpp.road.io/{CPO Name}
- Updated FLEXeCHARGE URL to the new endpoint prod.flexecharge.com/{Site ID}
Firmware 1.8.1
- Various performance updates and small bug fixes
Customisation c1.13
Added backoffices:
- Charge Unix
- ev.energy
- Interparking
- Nexxtmove
- Qovoltis
- Solnet EV
- Swish
- Enables PCard usage for Peblar off-the-shelf products (functionality enabled from release 1.9.0)
Firmware 1.8.1
- Various performance updates and small bug fixes
Customisation c1.12
- Enabled Connect Hub features
- Added multiple backoffices, for the full list see our integrations page
Firmware 1.8.0
- Automatic selection of first-found HomeWizard
- 1- to 3-phase switching for solar charging
- Configurable phase imbalance in group Leader for Germany and Austria
- Local download of charging session data improvements
- 150A CT coil support
- OCPP 1.6 ParentID support
- And more
Customisation c1.12
- Enabled Connect Hub features
- Added multiple backoffices, for the full list see our integrations page
Features
- Download charging session data
- Easier local EMS controller detection via OCPP
Improvements
- Improved behaviour for ground monitoring error
- Improved DNS resolving
- Improved HomeWizard discovery behaviour
- Various connectivity improvements
- Multiple other improvements
OCPP backoffice updates
- Added Blossom, Bywatt, eMabler, Eneco (LAN), Eneco (SIM), Etecnic, Evenli, Laadkompas, LMS (Wurth) REEV and Scoptvision to the supported backoffice list
- Added Heijmans, Van Mossel NL and Van Mossel BE as subselections for E-Flux
Other updates
- Removed entries indicating (3rd party SIM), as installers can adjust SIM settings manually during commissioning
- Enabled functionality that reduced the possibility of paused charging sessions when dynamic load balancing is applied
- Backoffice and SIM selection improvement: a dual dropdown list provides a complete and detailed overview of backoffices in the commissioning interface, making it easier to locate the correct backoffice during installation. SIM card settings can now be configured during commissioning, providing greater flexibility.
- Danish web interface: the commissioning and web interface is now available in Danish.
- Support for new Modbus meters: operation of the charger is now supported with additional Modbus meters. This support enables features like solar charging and the household power slider without the need of a smart meter. Carlo Gavazzi EM112/EM3x0 (RTU), Siemens PAC 2200 (TCP), Phoenix Contact EEM-Mxx7x (TCP), Socomec Countis E2x (TCP), Socomec Countis E4x (TCP).
- Resume charging after power outage: the charger now resumes ongoing charging sessions after a power outage.
- Added Groendus, OK, Gridfluxx, EVWAY, ConnectNed to backoffice list
- Adjusted URL FLEXeCHARGE to new production environment
- Enabled the household power slider by default for chargers using dynamic load balancing and/or solar charging, except those only using CT coils for measurement
- Various fixes and improvements
- Fixed dynamic load balancing with HomeWizard P1 meter not working on a 1-phase household
- Various fixes and improvements
- Local REST API and Modbus TCP API: these two local APIs can be exposed to use for local control of the charger.
- Group load balancing over ethernet: load balancing in a group of chargers can now be performed using ethernet.
- Household power slider: we introduce a slider that can be used to manage household power consumption.
- Multiple cable (un)lock options for socket models: with this feature, the cable can be permanently fixed to the socket charger. The socket can also be unlocked in the web interface.
- Showing error code on display: the active error code is shown on the display for easier troubleshooting.
- Improved commissioning flow: the commissioning process has been streamlined with additional diagnostics and configurations to incorporate new features.
- UI and UX improvements of the local web interface: improvements made to the user interface and user experience to enhance user-friendliness for the consumer.
- New customisation firmware for Peblar (1.8): this contains the formatting changes for the Peblar web interface (colours, font and more).
- Phase imbalance support in the commissioning interface: this ensures that the charger is configured in a way that it will not exceed the maximum phase imbalance caused by charging an EV.
- Support of new measurement sources: HomeWizard WiFi kWh meter 1-phase and 3-phase MID supported.
- Multiple improvements: firmware updates of Peblar chargers prioritise ethernet and WiFi over LTE, enhanced WiFi connectivity, multiple OCPP improvements.
- Various fixes and improvements
New backend support
- Laadnet
- Mobiflow
- Improved commissioning flow: we have streamlined the commissioning process to incorporate these new features, ensuring a more straightforward experience for installers.
- Support of new measurement sources: we have expanded our list of supported measurement sources to include the Phoenix EMPro and Xemex Smart Charge Controller, enabling dynamic (group) load balancing capabilities.
- Current limiter: users can now easily adjust the charging current directly through the web interface, offering greater customisation and control.
- Solar charging: users now have the flexibility to charge with solar generated power, providing greater control over their energy consumption.
- Dynamic group load balancing: by integrating load balancing with the group load balancing feature, we have optimised efficiency by utilising the measurement source as an input for the leader module within the daisy-chain configuration.
- Improved diagnostics in web interface: we have implemented multiple diagnostic measurements within the web interface, providing users with enhanced insights and troubleshooting capabilities.
- Additional minor features and improvements: this update also includes several smaller enhancements, such as OCPP ClockAlignedDataInterval, CT coils readings via OCPP, the exposure of Eichrecht public key via OCPP, single phase commissioning, and dynamic load balancing improvements.
Can't find what you're looking for?Our support team is happy to help you find the right document.
Contact support